Datasheet

78M6610+PSU Data Sheet
5.4 Performance Specifications
Note that production tests are performed at room temperature.
5.4.1 Input Logic Levels
Parameter Condition Min Typ Max Unit
Digital high-level input voltage, V
IH
2
V
Digital low-level input voltage, V
IL
0.8 V
5.4.2 Output Logic Levels
Parameter
Condition
Min
Typ
Max
Unit
Digital high-level output voltage V
OH
I
LOAD
= 1 mA
V
3P3
0.4
V
I
LOAD
= 10 mA
V
3P3
-
0.6
V
Digital low-level output voltage V
OL
I
LOAD
= 1 mA 0 0.4 V
I
LOAD
= 10 mA
0.5 V
5.4.3 Supply Current
Parameter
Condition
Min
Typ
Max
Unit
V
3P3D
and V
3P3A
current
(compounded)
Normal Operation,
V
3P
=3.3V
8.1 10.3 mA
5.4.4 Crystal Oscillator
Parameter
Condition
Min
Typ
Max
Unit
XIN to XOUT Capacitance
3
1
pF
Capacitance to GND
XIN
XOUT
5
1
5
1
pF
pF
1
Guaranteed by design, not subject to test.
5.4.5 Internal RC Oscillator
Parameter
Condition
Min
Typ
Max
Unit
Nominal Frequency 20.000 MHz
Accuracy
±1.5
%
56 Rev 3