Datasheet
78M6610+PSU Data Sheet
3.7.5 AlarmReset Register (address 0x0F)
The AlarmReset register is used to clear an alarm by setting the corresponding bit.
Table 3-12: AlarmReset Registers Bit Assignments
Bit
Alarm/
Status
Default Function
23
DataReady
0
1 = Clear Alarm ; 0 = No Operation
22 OverTemp 0 1 = Clear Alarm ; 0 = No Operation
21 UnderTemp 0 1 = Clear Alarm ; 0 = No Operation
19
ExtOvTemp1
0
1 = Clear Alarm ; 0 = No Operation
18 ExtOvTemp2
0 1 = Clear Alarm ; 0 = No Operation
17-12 Not Used – Not used
11 Vsag 0 1 = Clear Alarm ; 0 = No Operation
10 Vsurge 0 1 = Clear Alarm ; 0 = No Operation
9 VdropOut 0 1 = Clear Alarm ; 0 = No Operation
8
OverVolt
0
1 = Clear Alarm ; 0 = No Operation
7 UnderVolt 0 1 = Clear Alarm ; 0 = No Operation
6 OverCurrent 0 1 = Clear Alarm ; 0 = No Operation
5
OverPower
0
1 = Clear Alarm ; 0 = No Operation
4 OverFreq 0 1 = Clear Alarm ; 0 = No Operation
3 UnderFreq 0 1 = Clear Alarm ; 0 = No Operation
2 Relay_On 0 1 = Clear Alarm ; 0 = No Operation
1 Zero_Cross 0 1 = Clear Alarm ; 0 = No Operation
0 Not Used – Not used
Rev 3 35