Datasheet
DS_1215F_003  73S1215F Data Sheet 
Rev. 1.4    75 
Clock Control Register (CKCON): 0x8E Å 0x01 
Table 79: The CKCON Register   
MSB   LSB 
–  – – – – CKWT.2 CKWT.1 CKWT.0
Bit Symbol  Function 
CKCON.7 –  
CKCON.6 –  
CKCON.5 –  
CKCON.4 –  
CKCON.3 –  
CKCON.2 CKWT.2 
These three bits determine the number of wait states (machine cycles) to 
insert when accessing the USB SFRs: 
000 = 0 (not to be used). 
001 = 1 wait state. Use when MPU clock is <12MHz. 
010 = 2 wait states. Use when MPU clock is between 12 and 16MHz. 
011 = 3 wait states. Use when MPU clock is 24MHz. 
100 = 4 wait states. 
101 = 5 wait states. 
110 = 6 wait states. 
111 = 7 wait states. 
CKCON.1 CKWT.1 
CKCON.0 CKWT.0 