4 Country Specific Settings
The 73M1x66B Reference Driver supports global compliance parameters for each DAA device it
manages. When selected for a specific country code using M1966_CH_INIT, the following predefined
parameters will be applied:
1. AC termination impedance AC impedance register value.
2. DC termination mask DC mask value.
3. Ring Detection Ring detection threshold value.
4. Automatic CID Enable Automatically enter CID state when on hook.
5. Use Seize State If set, the driver enter seize state for 350 ms before setting ENNOM (refer to the
73M1x66B Data Sheet, Section 10.2 DC Termination, for the detail explanation of the seize state).
These parameters are defined in the Country Code Parameter files (m1966_cntry_tbl.c) and can be
changed as required. The list of the country codes supported can be found in Appendix A.