Owner's manual
UG_1x66B_016 73M1866B/73M1966B Implementer’s Guide
Rev. 1.3 15
3.2.3 Initial Line State Configuration
The default condition of the device is to be on hook after reset and startup.
The registers used in this procedure are:
0x05 ENGPIO7 ENGPIO6 ENGPIO5 ENPCLKDT ENAPOL ENDET ENSYNL ENRGDT
Write X X X X 1 X 1 X
0x12
OFH
ENDC
ENAC
ENSHL
ENLVD
ENFEL
ENDT
ENNOM
Write
0
0
0
0
0
1
0
0
0x13 DCIV1 DCIV0 ILM RSVD PLDM OVDTH IDISPD Res
Write
VAL1[1:0]
0 0 0 0 0 0
0x14
TXBST
DAA1
DAA0
Res
RXBST
RLPNH
RXG1
RXG0
Write X X X 0 X X X X
0x15 ENOLD DISNTR Res CIDM THEN ENUVD ENOVD ENOID
Write 0 0 0 0 1 0 0 0
0x16
TXEN
RXEN
RLPNEN
ATEN
ACZ3
ACZ2
ACZ1
ACZ0
Write 1 1 0 1
VAL2[3:0]
0x17
Res Res RXOCEN Res Res Res Res Res
Write
0 0 0 0 0 0 0 0
The temporary variables defined in this procedure are:
VAL1 = Set the DCIV bits to the desired DC current voltage characteristic as defined in the
73M1866B/73M1966B Data Sheet.
VAL2 = System appropriate value for ACZ[3:0].
Begin
1. Set ENAPOL =1 and ENSYNL = 1, to allow automatic polling of line side registers (write RG05 =
xxxx_1x1x).
2. Set ENFEL = 1, OFH = ENDC = ENAC = ENSHL = ENVLD = ENDT = ENNOM = 0 (Write RG12 =
0x40).
3. Set ILM = RSVD = PLDM = OVDTH = IDISPD = Res = 0, DCIV = VAL1 (Write RG13 =
Val1[1:0]00_0000).
4. Write RG14 = xxx0_xxxx.
5. Set THEN = 1, set ENOLD = DISNTR = CHPSEN = CIDM = ENUVD = ENOVD = ENOID = 0 (Write
RG15 = 0000_1000).
6. Set TXEN = RXEN = ATEN = 1, RLPNEN = 0 and ACZ[3:0] =VAL2[3:0] (Write RG16 =
1101_VAL2[3:0]).
7. Set RXOCEN and all Res bits in RG17 = 0 (write RG17 = 0x00).
End
After this point the host may selectively enable other on-hook operations such as ring detection or CID
mode.