If TEMP_PWR selects VBAT_RTC when the battery is nearly discharged, the temperature measurement 
may not finish.  In this case, firmware may complete the measurement by selecting V3P3D 
(TEMP_PWR = 1). 
Table 45: I/O RAM Registers for Temperature and Battery Measurement 
Name  Location  Rst  Wk  Dir  Description 
TBYTE_BUSY 
28A0[3]  0  0  R 
Indicates that hardware is still writing the 0x28A0 
byte. Additional writes to this byte are locked out 
while it is one. Write duration could be as long as 6 ms. 
TEMP_PER[2:0] 
28A0[2:0]  0  –  R/W 
Sets the period between temperature measurements. 
Automatic measurements can be enabled in any 
mode (MSN, BRN, LCD, or SLP). 
TEMP_PER 
Time 
0 
Manual updates (see TEMP_START) 
1-6 
2 ^ (3+TEMP_PER) (seconds) 
7 
Continuous 
TEMP_BAT 
28A0[4]  0  –  R/W 
Causes VBAT to be measured whenever a 
temperature measurement is performed. 
TEMP_START 
28B4[6]  0  –  R/W 
TEMP_PER[2:0] must be zero in order for TEMP_START 
to function. If TEMP_PER[2:0] = 0, then setting 
TEMP_START starts a temperature measurement. 
Ignored in SLP and LCD modes. Hardware clears 
TEMP_START when the temperature measurement is 
complete. 
TEMP_PWR 
28A0[6]  0  –  R/W 
Selects the power source for the temperature sensor:  
1 = V3P3D, 0 = VBAT_RTC. This bit is ignored in 
SLP and LCD modes, where the temperature sensor is 
always powered by VBAT_RTC. 
TEMP_BSEL 
28A0[7]  0  –  R/W 
Selects which battery is monitored by the 
temperature sensor: 1 = VBAT, 0 = VBAT_RTC  
TEMP_TEST[1:0] 
2500[1:0]  0  –  R/W 
Test bits for the temperature monitor VCO.  
TEMP_TEST must be 00 in regular operation. Any 
other value causes the VCO to run continuously with 
the control voltage described below. 
TEMP_TEST 
Function 
00 
Normal operation 
01 
Reserved for factory test 
1X 
Reserved for factory test 
STEMP[10:3] 
STEMP[2:0] 
2881[7:0] 
2882[7:5] 
R 
R 
The result of the temperature measurement. 
The STEMP[10:0] value may be obtained in C with a 
single 16-bit read and divide by 32 operation as 
follows: 
volatile int16_t xdata STEMP _at_0x2881; 
fa = (float)(STEMP/32); 
BSENSE[7:0] 
2885[7:0] 
– 
– 
R 
The result of the battery measurement.  
BCURR 
2704[3]  0  0  R/W 
Connects a 100 µA load to the battery selected by 
TEMP_BSEL. 