Datasheet
  71M6543F/71M6543G Data Sheet 
v2    127 
5.3.10  CE Calibration Parameters 
Table 85 lists the parameters that are typically entered to effect calibration of meter accuracy. 
Table 85: CE Calibration Parameters 
CE  
Address 
Name  Default  Description 
0x10 
CAL_IA 
16384 
These constants control the gain of their respective channels. The 
nominal value for each parameter is 2
14 
= 16384.  The gain of each 
channel is directly proportional to its CAL parameter. Thus, if the 
gain of a channel is 1% low, CAL should be increased by 1%. 
0x11 
CAL_VA 
16384 
0x13 
CAL_IB 
16384 
0x14 
CAL_VB 
16384 
0x16 
CAL_IC 
16384 
0x17 
CAL_VC 
16384 
0x19 
CAL_ID 
16384 
0x12 
PHADJ_A 
0 
These constants control the CT phase compensation. No  
compensation occurs when PHADJ_X = 0. As PHADJ_X is increased, 
more compensation (lag) is introduced. The range is ± 2
15
 – 1. If it 
is desired to delay the current by the angle Φ, the equations are: 
Φ⋅−
Φ
=
TAN
TAN
XPHADJ
0168.01714.0
029615.0
2_
20
 at 60Hz 
Φ⋅−
Φ⋅
=
TAN
TAN
XPHADJ
01226.01430.0
0206.0
2_
20
 at 50Hz 
0x15 
PHADJ_B 
0 
0x18 
PHADJ_C 
0 
0x12 
DLYADJ_A 
0 
The shunt delay compensation is obtained using the equation 
provided below: 
( )
+
+
∆+∆=
s
ss
reesrees
f
f
c
b
f
f
ab
f
f
a
XDLYADJ
π
ππ
π
2
sin
2
cos2
2
cos
360
2
21.01_
22
14
degdeg
where: 
Aa 2=
1
2
+= Ab
 = 2
+ 4
2
+ 2 
f is the mains frequency 
f
s
 is the sampling frequency 
The table below provides the value of A for each channel: 
Channel 
Value of A 
(decimal) 
D  YADJ_A 
13840 
DLYADJ_B 
11693 
DLYADJ_C 
9359 
0x15 
DLYADJ_B 
0 
0x18 
DLYADJ_C 
0 
Note: 
The current sensor inputs are not assigned to the A, B and C phases in a fixed manner. The 
assignments of phases A, B and C depends on how the IADC0-1, IADC2-3, IADC4-5, IADC6-7 current 
sensing inputs are connected in the meter design. The CE code must be aware of these connections. 
See Figure 31 and Figure 32 for typical meter configurations. VADC8, VADC9 and VADC10 are 
assigned to voltage phases VA, VB and VC in a fixed manner, respectively. 
The CE addresses listed in this table are assigned to phases A, B and C as indicated by their names. 