Table 83: CE Pulse Generation Parameters 
CE  
Address 
Name  Default  Description 
0x21 
WRATE 
227 
Kh = VMAX*IMAX*K / (WRATE*N
ACC
*X) Wh/pulse 
where: 
K = 76.3594 when used with local sensors (CT or shunt) 
K = 54.5793 when used with 71M6xx3 remote sensors 
0x22 
KVAR 
6444 
Scale factor for VAR measurement. 
0x23 
SUM_PRE 
2184 
Number of samples per accumulation interval, as specified in 
SUM_SAMPS[12:0], I/O RAM 0x2107[4:0], 0x2108[7:0] 
 (N
ACC
). 
0x45 
APULSEW 
0 
Wh pulse (WPULSE) generator input to be updated by the MPU 
when using external pulse generation. The output pulse rate is:  
APULSEW * F
S 
* 2
-32 
* WRATE * X * 2
-14
.  
This input is buffered and can be updated by the MPU during a 
conversion interval. The change takes effect at the beginning of 
the next interval. 
0x46 
WPULSE_CTR 
0 
Counter for WPULSE output. 
0x47 
WPULSE_ FRAC 
0 
Unsigned numerator, containing a fraction of a pulse. The value 
in this register always counts up towards the next pulse. 
0x48 
WSUM_ ACCUM 
0 
Roll-over accumulator for WPULSE. 
0x49 
APULSER 
0 
VARh (VPULSE) pulse generator input. 
0x4A 
VPULSE_CTR 
0 
Counter for VPULSE output. 
0x4B 
VPULSE_ FRAC 
0 
Unsigned numerator, containing a fraction of a pulse.  The value 
in this register always counts up towards the next pulse. 
0x4C 
VSUM_ACCUM 
0 
Roll-over accumulator for VPULSE. 
Other CE Parameters 
Table 84 shows the QUANT CE parameters used for suppression of noise due to scaling and truncation 
effects. The equations for calculating the LSB weight of each QUANT parameter are provided at the 
bottom of Table 84.   