Datasheet
71M6543F/71M6543G Data Sheet   
120    v2 
Table 76: CECONFIG Bit Definitions (CE RAM 0x20) 
CECONFIG 
bit 
Name  Default  Description 
23 
Reserved 
0 
Reserved (can be used by the MPU to indicate that the 
71M6x03 is being used; CE does not use this). 
22 
EXT_TEMP 
0 
When 1, the MPU controls temperature compensation via the 
GAIN_ADJn (CE RAM 0x40-0x42), when 0, the CE is in control. 
21 
EDGE_INT 
1 
When 1, XPULSE produces a pulse for each zero-crossing of 
the mains phase selected by FREQSEL[1:0] , which can be used 
to interrupt the MPU. 
20 
SAG_INT 
1 
When 1, activates the YPULSE/SEGDIO7 output when a sag is 
detected (see 2.5.10
) on the phase selected with FREQ-
SEL[1:0].  
19:8 
SAG_CNT 
218 
(0xDA) 
The number of consecutive voltage samples below SAG_THR 
(CE RAM 0x24) before a sag alarm is declared. The default value 
is equivalent to 100 ms.  
7:6 
FREQSEL[1:0]
0 
FREQSEL[1:0] selects the phase to be used for the frequency 
monitor, sag detection, the phase-to-phase lag calculation and 
for the zero crossing counter (MAINEDGE_X, CE RAM 0x83). 
FREQ SEL[1:0] 
Phase  
Selected 
Phases Selected 
PH_AtoB_X 
PH_AtoC_X 
0 
0 
A 
A-B 
A-C 
0 
1 
B 
B-C 
B-A 
1 
0 
C 
C-A 
C-B 
1 
1 
Not allowed 
5 
EXT_PULSE 
1 
When zero, causes the pulse generators to respond to internal 
data. WPULSE = WSUM_X (CE RAM 0x84), VPULSE = VARSUM_X 
(CE RAM 0x88.) Otherwise, the generators respond to values the 
MPU places in APULSEW and APULSER (CE RAM 0x45 and 0x49) 
4:2 
Reserved 
0 
Reserved. 
1 
PULSE_FAST 
0 
When PULSE_FAST = 1, the pulse generator input is increased 
16x.  When PULSE_SLOW = 1, the pulse generator input is 
reduced by a factor of 64. These two parameters control the 
pulse gain factor X (see table below). Allowed values are either 
1 or 0. Default is 0 for both (X = 6). 
PULSE_FAST  PULSE_SLOW  X 
0 
0 
1.5 * 2
2
 = 6 
0 
1 
1.5 * 2
-4
 = 0.09375 
1 
0 
1.5 * 2
6
 = 96 
1 
1 
Do not use 
0 
PULSE_SLOW
0 
The FREQSEL[1:0] field in CECONFIG (CE RAM 0x20[7:6]) selects the phase that is utilized to generate a sag 
interrupt. Thus, a SAG_INT event occurs when the selected phase has satisfied the sag event criteria as 
set by the SAG_THR (CE RAM 0x24) register and the SAG_CNT field in CECONFIG (CE RAM 0x20[19:8]). 
When the SAG_INT bit (CE RAM 0x20[20]) is set to 1, a sag event generates a transition on the YPULSE 
output. After a sag interrupt, the MPU should change the FREQSEL[1:0] setting to select the other phase, 
if it is powered. Even though a sag interrupt is only generated on the selected phase, all three phases 
are simultaneously checked for sag. The presence of power on a given phase can be sensed by directly 
checking the SAG_A, SAG_B and SAG_C bits in CESTATUS (CE RAM 0x80[0:1]). 
The EXT_TEMP bit enables temperature compensation by the MPU, when set to 1. When 0, internal (CE) 
temperature compensation is enabled. 