Datasheet
71M6543F/71M6543G Data Sheet   
118    v2 
5.3.6  CE Front-End Data (Raw Data) 
Access to the raw data provided by the AFE is possible by reading CE RAM addresses 0 through A, as 
shown in Table 72. In the expression MUXn_SEL[3:0] = x, ‘n’ refers to the multiplexer frame time slot number 
and ‘x’ refers to the desired ADC input number or ADC handle (i.e., IADC0 to VADC10, or simply 0 to 10 
decimal). 
The 71M6543 can support up to eleven sensor inputs, when all the current sensors are configured as 
single-ended inputs. If all the current sensor inputs are configured as differential (recommended for 
best performance), the number of input sensor channels is reduced to seven (i.e., IADC0-1, IADC2-3,  
IADC4-5, IADC6-7, VADC8, VADC9 and VADC10). The MUXn_SEL[3:0] column in Table 72 shows the 
MUXn_SEL handles for the various sensor input pins. For example, if differential mode is enabled via 
control bit DIFF0_E = 1 (I/O RAM 0x210C[4]), then the IADC0-IADC1 input pins are combined together to 
form a single differential input and the corresponding MUXn_SEL handle is 0 (i.e., handle 1 is then unused). 
Similarly, the CE RAM location column provides the CE RAM address where the corresponding sample data 
is stored. Continuing with the same example, if DIFF0_E = 1, the corresponding CE RAM location where the 
samples for the IADC0-IADC1 differential input are stored is CE RAM 0. 
The IADC2-3, IADC4-5 and IADC6-7 inputs can be configured as direct-connected sensors (i.e., directly 
connected to the 71M6543) or as remote sensors (i.e., using a 71M6xx3 Isolated Sensor). For example, if the 
IADC2-3 remote sensor is disabled by RMT2_E = 0 (I/O RAM 0x2007[3]) and differential mode is enabled by 
DIFF2_E = 1 (I/O RAM 0x210C[4]), then IADC2-IADC3 form a differential input with a MUXn_SEL handle of 2 
(i.e., handle 3 is then unused), and the corresponding samples are stored in CE RAM location 2. If the 
remote sensor enable bit RMT2_E = 1, DIFF2_E = x (don’t care), then the MUXn_SEL handle is not required 
(i.e., the sensor is not connected to the 71M6543 multiplexer, so MUXn_SEL does not apply), and the 
samples corresponding to this remote differential IADC2-IADC3 input are stored in CE RAM location 2 
directly by the digital isolation interface (see Figure 2). 
The voltage sensor inputs (VADC8, VADC9 and VADC10) are always single-ended inputs and cannot be 
configured as remotes, so they do not have any associated configuration bits. VADC8 (VA) has a 
MUXn_SEL handle value of 8, and its samples are stored in CE RAM location 8. VADC9 (VB) has a 
MUXn_SEL handle value of 9 and its samples are stored in CE RAM location 9. VADC10 (VC) has a 
MUXn_SEL handle value of 10 and its samples are stored in CE RAM location 10. 
Table 72: CE Raw Data Access Locations 
Pin 
MUXn_SEL
 Handle 
CE RAM Location 
DIFF0_E 
DIFF0_E 
0 
1 
0 
1 
IADC0 
0 
0 
0 
0 
IADC1 
1 
1 
RMT2_E, DIFF2_E 
RMT2_E, DIFF2_E 
0,0 
0,1 
1,0 
1,1 
0,0 
0,1 
1,0 
1,1 
IADC2 
2 
2  -  - 
2 
2  2*  2* 
IADC3 
3 
3 
RMT4_E, DIFF4_E 
RMT4_E, DIFF4_E 
0,0 
0,1 
1,0 
1,1 
0,0 
0,1 
1,0 
1,1 
IADC4 
4 
4  -  - 
4 
4  4*  4* 
IADC5 
5  5 
RMT6_E, DIFF6_E
RMT6_E, DIFF6_E
0,0 
0,1 
1,0 
1,1 
0,0 
0,1 
1,0 
1,1 
IADC6 
6 
6  -  - 
6 
6  6*  6* 
IADC7 
7 
7 
There are no configuration bits for VADC8, 9, 10 
VADC8 (VA) 
8 
8 
VADC9 (VB) 
9 
9 
VADC10 (VC) 
10 
10 
*Remote interface data 