Datasheet
  71M6541D/F/G and 71M6542F/G Data Sheet       
Rev 4    135 
5.3.10  Other CE Parameters 
Table 91 shows the CE parameters used for suppression of noise due to scaling and truncation effects. 
Table 91: CE Parameters for Noise Suppression and Code Version 
CE  
Address 
Name  Default  Description 
0x25 
QUANT_VA 
0 
Compensation factors for truncation and noise in voltage, current, 
real energy and reactive energy for phase A. 
0x26 
QUANT_IA 
0 
0x27 
QUANT_A 
0 
0x28 
QUANT_VARA 
0 
0x29 
†
QUANT_VB 
0 
Compensation factors for truncation and noise in voltage, current, 
real energy and reactive energy for phase B. 
†
 71M6542 only. 
0x2A 
QUANT_IB 
0 
0x2B 
QUANT_B 
0 
0x2C 
QUANT_VARB 
0 
0x38 
0x43453431 
CE file name identifier in ASCII format (CE41a01f). These values 
are overwritten as soon as the CE starts  
0x39 
0x6130316B 
0x3A 
0x00000000 
LSB weights for use with Local Sensors: 
)(10
08656
.
5
__
22
13
Amps
IMAXLSB
Ix
QUANT ⋅
⋅
=
−
For ce41a04, 
QUANT_Ix_LSB = 3.6212·10
-13
 · IMAX
2
 (Amps
2
) 
)(1004173.
1__
9
WattsIMAXVMAXLSBWxQUANT ⋅⋅⋅
=
−
For ce41a04, 
QUANT_Wx_LSB = 7.4162·10
-10
 · VMAX · IMAX (Watts) 
)(
1004173
.1
__
9
VarsIMAXVMAXLSB
VARxQUANT ⋅⋅⋅
=
−
For ce41a04,
 QUANT_VARx_LSB = 7.4162 · 10
-10 
 · VMAX · IMAX (Vars) 
LSB weights for use with the 71M6x01 isolated sensors: 
)(1038392.1__
2212
AmpsIMAXLSBIxQUANT ⋅⋅=
−
)(1071829.1__
9
WattsIMAXVMAXLSBWxQUANT ⋅⋅⋅=
−
)(1071829.1__
9
VarsIMAXVMAXLSBVARxQUANT ⋅⋅⋅=
−