Manual
71M6541 Demo Board REV 3.0 User’s Manual 
30    Rev 4.0 
1.10.3 LSB VALUES IN CE REGISTERS 
Table 1-8: CE Registers and Associated LSB Values 
Register Name 
LSB Value 
Comment 
W0SUM_X 
1.55124*10
-12
*IMAX*VMAX 
The real energy for element 1 (IA, VA), measured in Wh per accumu-
lation interval 
VAR0SUM_X 
1.55124*10
-12
*IMAX*VMAX 
The reactive energy for element 1 (IA, VA), measured in VARh per 
accumulation interval 
W1SUM_X 
1.55124*10
-12
*IMAX*VMAX 
The real energy for element 2 (IB, VA), measured in Wh per accumu-
lation interval 
VAR1SUM_X 
1.55124*10
-12
*IMAX*VMAX 
The reactive energy for element 2 (IB, VA), measured in VARh per 
accumulation interval 
I0SQSUM_X 
2.55872*10
-12
*IMAX*VMAX 
The sum of squared current samples in element 1 (IA). This value is 
the basis for the I
RMS
 calculation performed in the MPU. 
I1SQSUM_X 
2.5587*10
-12
*IMAX*VMAX 
The sum of squared current samples in element 2 (IB). This value is 
the basis for the I
RMS
 calculation performed in the MPU. 
V0SQSUM_X 
9.40448*10
-13
*IMAX*VMAX 
The sum of squared voltage samples in element 1 (VA). 
V1SQSUM_X 
9.40448*10
-13
*IMAX*VMAX 
The sum of squared voltage samples in element 1 (VA). This value is 
not used for EQU 0 or EQU 1. 
1.10.4 CALCULATING IMAX AND KH 
The relationship between the resistance of the shunt resistors and the system variable IMAX is determined by 
the type of Remote Sensor Interface used, and is as follows: 
IMAX = 0.044194 / R
S
 for the 71M6601 
IMAX = 0.012627 / R
S
 for the 71M6201 
Where: 
R
S
 = Shunt resistance in Ω 
Table 1-9 shows 
IMAX values resulting from possible combinations of the shunt resistance value and the type 
of 71M6X0X Remote Sensor Interface used for the application. All values are for 
PRE_E = 0 (I/O RAM register 
2704 = 0x90), 
PULSE_FAST = 0, and PULSE_SLOW = 0. The CE register at address 0x30 has to be adjusted 
as shown in the rightmost column of the table. 