Datasheet
71M6521DE/DH/FE Data Sheet 
Rev 3    Page: 95 of 107 
TEMPERATURE SENSOR 
PARAMETER 
CONDITION 
MIN 
TYP 
MAX 
UNIT 
Nominal Sensitivity (S
n
) 
† 
T
A=25ºC, TA=75ºC, 
FIR_LEN = 1 
Nominal relationship: 
 N(T)= S
n
*(T-T
n
)+N
n
  -2180    LSB/ºC 
Nominal (N
n
)
 † † 
    1.0    10
6
 LSB
Temperature Error
†
+
−
−=
n
n
n
T
S
NTN
TERR
))((
T
A = -40ºC to +85ºC 
Tn = 25°C 
-10
1
    +10
1
  ºC 
1
Guaranteed by design; not production tested. 
† 
LSB values do not include the 9-bit left shift at CE input. 
†† 
N
n
 is measured at T
n
 during meter calibration and is stored in MPU or CE for use in temperature calculations.  










