TEMPERATURE SENSOR
PARAMETER
CONDITION
MIN
TYP
MAX
UNIT
Nominal Sensitivity (S
n
)
†
T
A=25ºC, TA=75ºC,
FIR_LEN = 1
Nominal relationship:
N(T)= S
n
*(T-T
n
)+N
n
-2180 LSB/ºC
Nominal (N
n
)
† †
1.0 10
6
LSB
Temperature Error
†
+
−
−=
n
n
n
T
S
NTN
TERR
))((
T
A = -40ºC to +85ºC
Tn = 25°C
-10
1
+10
1
ºC
1
Guaranteed by design; not production tested.
†
LSB values do not include the 9-bit left shift at CE input.
††
N
n
is measured at T
n