Rev 3    Page: 85 of 107 
CECONFIG 
[bit] 
Name  2BDefault  Description 
[15:8] 
SAG_CNT 
80 
(0x50) 
Number of consecutive voltage samples below SAG_THR before a sag 
alarm is declared. The maximum value is 255. SAG_THR is at address 
0x14. 
[7]  --  0  Unused 
[6] 
FREQSEL 
0  Selected phase for frequency monitor (0 = A, 1 = B). 
[5] 
EXT_PULSE 
1 
When zero, causes the pulse generators to respond to WSUM_X and 
VARSUM_X. Otherwise, the generators respond to values the MPU places 
in APULSEW and APULSER. 
[4]  --  0  Unused 
[3] 
IB_SHUNT 
0 
When 1, the current gain of channel B is increased by 8. The gain factor 
controlled by In_SHUNT is referred to as In_8 throughout this document. 
[2] 
IA_SHUNT 
0  When 1, the current gain of channel A is increased by 8.  
[1] 
PULSE_FAST 
0 
When PULSE_SLOW = 1, the pulse generator input is reduced by a factor of 
64. When PULSE_FAST = 1, the pulse generator input is increased 16x. 
These two parameters control the pulse gain factor X (see table below). 
Allowed values are either 1 or 0. Default is 0 (X = 6). 
X 
PULSE_SLOW  PULSE_FAST 
1.5 * 2
2 
= 6  0  0 
1.5 * 2
6 
= 96  0  1 
1.5 * 2
-4 
= 0.09375  1  0 
1.5  1  1 
[0] 
PULSE_SLOW 
0 
CE TRANSFER VARIABLES 
When the MPU receives the XFER_BUSY interrupt, it knows that fresh data is available in the transfer variables. The 
transfer variables can be categorized as: 
1.  Fundamental energy measurement variables 
2.  Instantaneous (RMS) values 
3.  Other measurement parameters 
4.  Pulse generation variables 
5.  Current shunt variables 
6.  Calibration parameters 