Datasheet
71M6511/71M6511H 
Single-Phase Energy Meter IC 
DATA SHEET  
NOVEMBER 2010 
Page: 74 of 98  © 2005–2010 Teridian Semiconductor Corporation  V2.7 
A Maxim Integrated Products Brand 
Other CE Parameters 
The table below shows CE parameters used for suppression of noise due to scaling and truncation effects as well as scaling 
factors. 
CE 
Address 
Name  Default  Description 
2F 
22 
QUANTA 
QUANTB 
0 
0 
These parameters are added to the Watt calculation to compensate for input 
noise and truncation. 
LSB=(VMAX*IMAX / IA_8) *7.4162*10
-10
 W for phase A, and 
LSB=(VMAX*IMAX / IB_8) *7.4162*10
-10
 W for phase B 
34 
24 
QUANT_VARA 
QUANT_VARB 
0 
0 
These parameters are added to the VAR calculation to compensate for input 
noise and truncation. 
LSB = (VMAX*IMAX / IA_8) * 7.4162*10
-10
 W for phase A, and 
LSB = (VMAX*IMAX / IB_8) * 7.4162*10
-10
 W for phase B 
35 
23 
QUANT_IA 
QUANT_IB 
0 
0 
These parameters are added to compensate for input noise and truncation in 
the squaring calculations for I
2
 and V
2
. 
LSB=VMAX
2
*7.4162*10
-10
 V
2
, 
LSB= (IMAX
2
/IA_8
2
)*7.4162*10
-10
 A
2 
for phase A and 
LSB= (IMAX
2
/IB_8
2
)*7.4162*10
-10
 A
2 
for phase B. 
3B  KVAR 
6448 
12880 
Scale factor for the VAR calculation. The default value of 
KVAR should never 
need to be changed. 
for 
MUX_DIV = 1 
for 
MUX_DIV = 2 