Manual

6613_OMU_2+2S_URT_V1_00 Firmware Description Document UG_6613_060
18 Rev. 1.1
The U command is used for updating default values of the CE Data permanently in the flash. Before
issuing the U command, CE must first be turned off by the disable CE command.
An example of a U command is as follows:
>CE0
>]U
Additional examples of CE Data Access commands are provided in the following table:
] CE Data Access
Description: Allows user to read from and write to CE data space.
Usage: ] {Starting CE Data Address}{option}…{option}<CR>
Command
Combinations:
]saddr?<CR> Read 32-bit word in decimal.
]saddr??<CR> Read two consecutive 32-bit words in decimal.
]saddr???<CR> Read three consecutive 32-bit words in decimal.
]saddr$<CR> Read 32-bit words in hex.
]saddr$$<CR> Read two consecutive 32-bit words in hex.
]saddr$$$<CR> Read three consecutive 32-bit words in hex.
]U<CR> Update default version of CE Data in
FLASH. Important: The CE must be
stopped (CE0) before issuing this
command! Also, remember to restart
by executing the CE1 command prior to
attempting measurements.
Examples: ]40$<CR> Reads CE data word at address location 0x40 in
the hex format.
]40$$<CR> Reads CE data word at address location 0x40
and 0x41 in the hex format.
]40$$$<CR> Reads CE data word at address location
0x40,0x41 and 0x42 in the hex format.
]40?<CR> Reads CE data word at address location 0x40 in
the decimal format.
]40??<CR> Reads CE data word at address location 0x40
and 0x41 in the decimal format.
]40???<CR> Reads CE data word at address location
0x40,0x42 and 0x43 in the decimal format.
]7E=12345678<CR> Writes 0x12345678 to CE address location 0x7E
in the hex format.
]7E=12345678=9876ABCD<CR> Writes 0x12345678 to CE address location 0x7E
and 0x9876ABCD to CE address location 0x7F
in the hex format.
]7E=+2255<CR> Writes 2255 to CE address location 0x7E in the
decimal format.
]7E=+2255=-456<CR> Writes 2255 to CE address location 0x7E and
-456 to CE address location 0x7F in the decimal
format.