Manual

UG_6613_ 060 6613_OMU_2+2S_URT_V1_00 Firmware Description Document
Rev. 1.1 13
4.5.1.2 CALW Command
The CALW command calibrates the temperature, voltage, and power (instead of the current).
To calibrate channel 1, enter the following:
>CALW<CR> or CALW1<CR>
The response is:
TCal OK
VCal OK:
WCal 1 OK:
>
To calibrate channel 2, enter the CAL2 command:
>CALW2<CR>
The response is:
TCal OK
VCal OK:
WCal 2 OK:
>
The device calibrates the temperature, the voltage, and the power and save all values to flash.
The CALW3 command calibrates both channel 1 and channel 2.
The complete calibration commands are summarized in the following table:
Complete Calibration Commands
Description: Calibrates the IC.
Usage: CAL<channel> Calibrates temperature, then voltage,
and finally current for the given channel.
CAL1 = Calibrates channel 1
CAL2 = Calibrates channel 2
CAL3 = Calibrates channel 1 and 2
CALW<channel> Calibrates temperature, then voltage,
and finally power for the given channel.
CALW1 = Calibrates channel 1
CALW2 = Calibrates channel 2
CALW3 = Calibrates channel 1 and 2