Instruction Manual
UG_6612_ 017 6612_OMU_S2+2_URT_V1_14 Firmware Description Document
Rev. 1.0 33
Output
Location
(hex)
LSB Comment Example
Bit 17 – PFB_WB negative –
Wideband Power Factor Negative
Threshold Alarm for Outlet 2. Only
available is )F2 bit 2 is 1.
Bit 18– PFB_WB positive –
Wideband Power Factor Positive
Threshold Alarm for Outlet 2.
Bit 19 – MAXIT_WB – maximum
total wideband current exceeded on
both Outlet 1 and Outlet 2.
Bit 20 – MAXIT_NB – maximum
total narrowband current exceeded
on both Outlet 1 and Outlet 2.
Bit 21 – CREEP A Alert – Creep
Alert on Outlet 1.
Bit 22 – CREEP B Alert – Creep
Alert on Outlet 2.
Bit 23 – Line/Neutral Reversal
detected. Only available in non-
isolated mode (CESTATE, Bit 2=1)
Bit 24 – Reserved.
Bit 25 – Reserved.
Bit 26 – Unexpected Reset.
Bits 27-31 – Reserved.
Note: Duplicate of address 0x02
(see Table 2)
Irms_wb B
Overcurrent
Event Count
63
Counter increments on each edge
event.
If four wideband over current
events have occurred on Outlet 2:
)63?<CR>
Returns: +4
Vrms Under
Voltage
Event Count
64
Counter increments on each edge
event.
Note: Duplicate of address 0x04
(see Table 2).
If 4 under voltage events have
occurred:
)64?<CR>
Returns: +4
Vrms Over
Voltage
Event Count
65
Counter increments on each edge
event.
Note: Duplicate of address 0x06
(see Table 2).
If 4 over voltage events have
occurred:
)65?<CR>
Returns: +4
Vrms A 66 mV
Vrms voltage
Note: Duplicate of address 0x06
(see Table 2).
If the line voltage is 120 V
)66?<CR>
Returns:
+120.000
Watts B 67 mW
Outlet 2 active power
measurement (per second)
Note: Duplicate of address 0x47
(see Table 4).
If 120 Watts are measured on
Outlet 2
)67?<CR>
Returns:
+120.000
Wh B 68 mWh
Outlet 2 active accumulated energy
measurement (per hour)
Note: Duplicate of address 0x48
(see Table 4).
If 120 Wh are measured on
Outlet 2
)68?<CR>
Returns:
+120.000
Total Cost B 69 mUnits
Outlet 2 cost of Wh B
Note: Duplicate of address 0x49
(see Table 4).
If the total cost is 102.536 units on
Outlet 2
)69?<CR>
+102.536