Instruction Manual

UG_6612_ 017 6612_OMU_S2+2_URT_V1_14 Firmware Description Document
Rev. 1.0 21
Output
Location
(hex)
LSB Comment Example
Bit 15 PFB_NB negative
Narrowband Power Factor Negative
Threshold Alarm for Outlet 2. Only
available is )F2 bit 2 is 1.
Bit 16 PFB_NB positive
Narrowband Power Factor Positive
Threshold Alarm for Outlet 2.
Bit 17 PFB_WB negative
Wideband Power Factor Negative
Threshold Alarm for Outlet 2. Only
available is )F2 bit 2 is 1.
Bit 18PFB_WB positive
Wideband Power Factor Positive
Threshold Alarm for Outlet 2.
Bit 19MAXIT_WB maximum
total wideband current exceeded on
both Outlet 1 and Outlet 2.
Bit 20MAXIT_NB maximum
total
narrowband current exceeded on
both Outlet 1 and Outlet 2.
Bit 21CREEP A Alert Creep
Alert on Outlet 1.
Bit 22 CREEP B Alert Creep
Alert on Outlet 2.
Bit 23 Line/Neutral Reversal
detected. Only available in non-
isolated mode (CESTATE, Bit 2=1)
Bit 24 Reserved.
Bit 25 Reserved.
Bit 26 Unexpected Reset.
Bits 27-31 Reserved.
Irms_nb A
Overcurrent
Event Count
03 1
Counter increments on each edge
event.
If four narrowband over current
events have occurred on Outlet 1:
)03?<CR>
Returns: +4
Vrms Under
Voltage
Event Count
04 1
Counter increments on each edge
event.
If four under voltage events have
occurred:
)04?<CR>
Returns: +4
Vrms Over
Voltage
Event Count
05 1
Counter increments on each edge
event.
If four over voltage events have
occurred:
)05?<CR>
Returns: +4
Vrms A 06 mVrms Vrms voltage.
If the line voltage is 120 V
)06?<CR>
Returns: