UG_6612_ 017 6612_OMU_S2+2_URT_V1_14 Firmware Description Document
Rev. 1.0 15
4.5.2.4 CLT Command
The CLT command is used for the temperature calibration. With this command, the contents of CE
register 71 are read and entered into MPU register C0 and the contents are saved to flash. The CLT
command example is given below:
>CLT<CR>
The response is:
TCal OK
>
A summary of the atomic calibration commands are given in the table below:
CLxx Atomic Calibration
Commands
Description: Allows the user to Calibrate individual sections of the IC.
Usage: CLV Calibrates voltage only.
CLI1 Calibrate current on Outlet 1 only.
CLI2 Calibrate current on Outlet 2 only.
CLI3 Calibrate for current on both Outlet 1 and Outlet 2
only.
CLW1 Calibrate for power on Outlet 1 only.
CLW2 Calibrate for power on Outlet 2 only.
CLW3 Calibrate for power on both Outlet 1 and Outlet 2.
CLP Calibrate for phase on Outlet 1 only. Generally only
used when using current transformers.
CLP2 Calibrate for phase on Outlet 2 only. Generally only
used when using current transformers.
CLP3 Calibrate for phase on both Outlet 1 and Outlet 2.
Generally only used when using current transformers.
CLT Calibrate temperature only.
The commands that follow are mainly for advanced users and are included for reference only.