Installation Instructions

22
INSTALLATIONINSTRUCTIONS
Whenthedeclivityofthedrainpipedownwards
isover1/100,thereshouldnotbeanywinding.
Thetotallengthofthedrainpipewhenpulled
outtraverselyshallnotexceed20m,whenthe
pipeisoverlong,apropstandmustbeinstalled
topreventwinding.
Refertothefiguresontherightforthe
installationofthepipes.
1.5m~2m
Insulating
material
Downwarddeclivity
lowerthan1/100
Bend
Sshape
VP30
Downwarddeclivity
lowerthan1/100
Putasdeepaspossible
(about10cm)
Fig.43-9
Fig.43-10
Drainagetest
Checkwhetherthedrainpipeis
unhindered.
Newbuilthouseshouldhavethistest
donebeforepavingtheceiling.
5.6Wiring(Console)
CAUTION
Theapplianceshallbeinstalledinaccordance
withnationalwiringregualtions.
Theairconditionershoulduseseparatepower
supplywithratedvoltage.
Theexternalpowersupplytotheairconditioner
shouldhavegroundwiring,whichislinkedtothe
groundwiringoftheindoorandoutdoorunit.
Thewiringworkshouldbedonebyqualified
personsaccordingtocircuitdrawing.
Anall-poledisconnectiondevicewhichhasat
least3mmseparationdistanceinallpoleand
aresidualcurrentdevice(RCD)withtherating
ofabove10mAshallbeincorporatedinthefixed
wiringaccordingtothenationalrule.
Besuretolocatethepowerwiringandthe
signalwringwelltoavoidcross-disturbance.
Donotturnonthepoweruntilyouhave
checkedcarefullyafterwiring.
5.6.1Connectthecable
Theinstallationbearerofsensing
devicerotatedtoanotherside,andthen
takesoffcoverofelectricalbox.(Take
offtheelectricalboxifthecapacityis
18000btu/haswellasusingnetwork
function.)(RefertoFig.43-10)
Installationbearer
ofsensingdevice
Allthepicturesinthismanualarefor
explanationpurposeonly.Theymaybe
slightlydifferentfromtheairconditioner
youpurchased(dependonmodel).The
actualshapeshallprevail.
NOTE: