Operation Manual
1.Location in the following places may cause malfunction of the machine. (If unavoidable,
please consult your local dealer)
a. A place where there is flammable gas leakage.
b. There is salty air surrounding(near the coast).
c. There is caustic gas(the sulfide, for example) existing in the air (near a hot spring).
d. A place where can not bear the weight of the machine.
e. In kitchen where it is full of oil gas
f. There is strong electromagnetic wave existing.
g. There is acid or alkaline liquid evaporating.
h. A place where air circulation is not enough.
I.The appliance shall not be installed in the laundry
2. Electrical Insulation must be done on the air conditioner and the building complying to
National Regulations.
CAUTIONS
INSTALLATION LOCATIONS
HEIGHT BETWEEN CEILING AND FLOOR
INSTALLATION SPACE
Size A(mm) Ceiling Height
Above 330mm
Models
B
C
Wall
material
Up(B)
Sides(C)
Above 5cm Above 5cm Above 5cm
Above 100cm Above 100cm
Flammable
material
Fire-proof
structure
Fire-proof material
or other nonflammable
materials other than
metal
A
Ceiling
Above 250cm
Above
100cm
Above
100cm
Obstacle
Model
2.7m<h<3.2m
Installation height
INDOOR UNIT INSTALLATION
The signal"o"refers that the model suits the corresponding installation height.
12000Btu/h,18000Btu/h
10
Leaked refrigerant will generate poisonous gas if meeting fire.
Allowed Length and Drop of Pipes
Material and Size of the Pipes
Requirements are different when installing the outdoor unit.
Three lengths (3m,5m,10m) of pipes are available to purchase.
f6.35(1/4inch)
Copper Pipe for Air ConditionerPipe Material
Size(mm)
Gas side
Liquid side
Pipe external
diameter
Added wrench torque
9.52
15.88
32.7(3.33kgf.m) ~
61.8(6.3kgf.m)~75.4(7.7kgf.m)
F
F
Connection of the Refrigerant Pipe
Double-span should be used when connecting the pipes.
The wrench torque follow the below table:
39.9(4.07kgf.m)
(N.m)
Wrap the connecting pipes and cables together with tape,
but not including the drainage pipe. Drainage pipe can be
fixed along them separately.
Wrapping from the joint of outdoor unit to that of indoor unit,
each round of tape should cover half of its previous one.
Wrap the piping
!
CAUTION
REFRIGERANT PIPE INSTALLATION
Ventilate the air if there was any refrigerant leakage during the installation.
Make sure there is no refrigerant leakage after the installation.
Leaked refrigerant will generate poisonous gas if meeting fire.
Pipe external
diameter
Added wrench torque
12.7
19.05
49.5(5.04kgf.m) ~
97.2(9.9kgf.m)~118.6(12.1kgf.m)
F
F
60.3(6.16kgf.m)
(N.m)
Connecting pipes
Cables
Drainage pipe
19
F6.35
14.2(1.4kgf.m)~17.0 1.7kgf.m
18000Btu/h 42000Btu/h
24000Btu/h
Model
7K-12K 14K-19K
23K-28K 30K-48K
f9.52(3/8inch)
f6.35(1/4inch)
f12.7(1/2inch)
f15.8(5/8inch)
f9.52(3/8inch)
f12.7(1/2inch)
f19.05(3/4inch)
*7K-12K refers to the cooling capacity of duct type which is between 7000BTU/h and 12000BTU/h.
36000Btu/h
42000Btu/h,48000Btu/h