User's Manual

2 Electric Capability
3Environmental
No.
Item
3.1
Operating Temperature
The RCU shall be capable of operating in an ambient temperature range of 0ºC to +40ºC.
3.2
Operating Humidity
The device shall be capable of operating in a relative humidity range of 8% to 90%, non-condensing.
N0
Item
Test Requirements
2.0
IC IC Mcu
RTL8752CJF
2.1
remote control model
RC01
2.2
Carrier frequency
2402----2480MHZ
2.3
Working Voltage
DC 3v
2.4
Static Current
6uA~500uA
2.5
Working Current
<30mA
2.6
RF distance
Working Voltage(3V)
IR>8m IR 15°>6m RF>10m
2.7
Mouse operating distance
>10m
2.8
Supported Operating Systems
Android4.3 or above
2.9
Code Table
Refer to the Code Table
2.10
Schematic Diagram
Refer to Schematic Diagram
2.11
200times/day(0.5seconds/time), Battery life is around half year
2.12
2402~2480MHZ GFSK
2.13
-20dbm~10dbm
2.14
drift <±50KHz Carrier frequency offset <20Khz/50us
2.15
>-0.98dB
2.16
BT 4.0 BLE1
2.17
No Failure in each key Operation