User guide
86 Managing the Storage Solution
Figure 68. Identifying Member Drives Screen
You can also identify specific drives in an array by flashing its Drive Status LED, see ”Locate Drive”
beginning on page 95.
Rebuilding an Array
This option is designed for situations where the user wants to manually start a rebuild operation.
One scenario where this option would be used is if you inadvertently pulled the wrong drive from
a working array and that drive is now flagged as a failed drive, regardless of whether or not you re-
insert the drive quickly. If you do not have a hot spare defined, the array will not automatically begin
a rebuild operation. You must change the status of the flagged failed disk drive to a spare drive which
will clear the condition and initiate a rebuild.
1. Identify the “failed” drive displayed in the enclosure front view and click that drive icon.
The Drive Information Panel will open.