User guide
31MAXDATA SR1202 M1 – StorView
®
RAID User Guide
SNMP
Configuring SNMP Traps
StorView can be configured to send SNMP traps to any network management system. These traps
carry all the information that appears in the log entries for each level of severity.
All SNMP traps sent from StorView are received by the host SNMP Servers designated in the settings
window for the specified port and community.
1. From the Main screen click on the SETTINGS button.
2. Click the SNMP tab.
3. Enter the SNMP Server name or IP address of the host you wish to receive SNMP traps.
4. Enter the IP port on which the SNMP Server expects to receive traps. The default is 162.
5. Enter the Community to which the traps belongs. SNMP Servers may belong to several
different communities or receive packets for different communities.
6. Select the level of events you wish to be included in the traps. You can select from
Informational, Warning and Error types, see ”Event Logs” beginning on page 109.
Figure 13. Settings Screen - SNMP Tab
7. Click the APPLY button.
8. Test the configurations by clicking the TEST button.
You will receive a confirmation message that the test was successfully completed, and each addressee
will receive a “Test Message”. Click the CLOSE button.
9. Click the CLOSE button on the SETTINGS window.