User guide
133MAXDATA SR1202 M1 – StorView
®
RAID User Guide
StorView Server Event
Messages
Type [ID] Cause Action
The Server CGI script
was unable to return
CGI request results to
the GUI.
Error
[0x307 (775)]
The Server passed the
completed request
to the Server CGI
but for some reason
the request wasn’t
completed correctly by
the Server CGI script.
Retry request.
Quit StorView and all
connections accessing
this StorView Server,
wait 1 minute and
restart them.
Restart the system.
Start up is complete.
Information
[0xA01 (2561)]
The controller module
has been loaded by the
StorView Server.
No action necessary.
Several failures
encountered while
trying to communi-
cate with the RAID
controller.
Error
[0xA03 (2563)]
Several commands
have been sent through
a known good path but
they have failed.
Ensure that the paths
and hardware are
operational.
Successful communi-
cation with controller
after several failures.
Information
[0xA04 (2564)]
A known failed path
is now functional and
passed retest.
No action necessary.
Failed Drives Codes
The controller maintains a list of failed drives. Drives are listed in the following format:
Failed Drive:xx SN: yy yy yy yy yy yy
Reason Code
The reason code may be one of the following:
Reason Code Reason Action
Drive Timeout The drive has either timed out
or been removed.
Re-insert the disk drive.
Replace the disk drive.
Command: xx Sense Key: yy Ext
Sense: zz
The drive has failed for the
specified command, with the
indicated SCSI sense key and
extended sense key.
Replace the disk drive.