User guide
131MAXDATA SR1202 M1 – StorView
®
RAID User Guide
StorView Server Event
Messages
Type [ID] Cause Action
A user <name> has
logged out the Server
from IP address:
<IP_address>.
Information
[0x106 (263)]
A specific user has
logged out of the
StorView Server from
the specified IP address
location. (The host
name was not avail-
able.)
No action required.
A user <name> has
logged out the Server
from Host: <host
name>, IP Address:
<IP_address>.
Information
[0x107 (264)]
A specific user has
logged out of the Stor-
View Server from the
specified host and IP
address location.
No action required.
The multicast address
is not configured. No
communication will
take place with other
servers.
Warning
[0x201 (513)]
The setting “Multicast
-
Port” is not setup in the
db/IP.db file. The setting
was removed or the file
became corrupt.
Open the file <StorView
folder>\db\IP.db in a
text editor, and add the
following line: Multi-
castPort=9191. Save the
file and start StorView
and press the Rescan
button or restart the
StorView service.
Multicast socket crea
-
tion failure: <reason>
Warning
[0x202 (514)]
StorView could not
setup the necessary
communication paths
to talk to other Stor-
View Servers. The
specific cause will
be specified in the
<reason> appended to
the message.
Change the multicast
port used by StorView.
Note that all StorView
servers must commu-
nicate with each other
on the same multicast
port. If the setting is
changed on one, they
must be changed on all
StorView Servers.
Open the file <StorView
folder>\db\IP.db in a
text editor, and change
the following line:
MulticastPort=<port
number>. Save the file
and start StorView and
press the Rescan button
or restart the StorView
service.