Enclosure Event
Messages
Type [ID] Cause Action
Temperature sensor
<zz> is in a critical state.
Error
[0xC6D (3181)]
Temperature sensors
are reporting enclosure
temperatures have
reached the threshold
of 70 °C.
Automatic system
shutdown will begin. In
Active-Active configu
-
rations, one controller
will shutdown its
partner and shutdown
the drives, then itself.
Ensure that both
cooling fans are
operating normally.
(Replace if needed.)
If the fans are set
to automatic speed
control, place the
jumper on the Cooling
fan module circuit
board to force the fans
to high speed.
If the environment
ambient temperature
is high, reduce the
ambient temperature.
Ensure that the airflow
is not blocked or
restricted on the enclo-
sure.
Alarm is Off (Muted).
Information
[0xC6E (3182)]
No condition being
reported.
Alarm muted.
No action necessary.
User pressed the Alarm
Mute button on the ops
panel.
Alarm is Intermittent. Error
[0xC6E (3182)]
A condition caused
the alarm to sound
every two minutes until
muted.
Press the Alarm Mute
button on the ops panel
and isolate the cause of
the alarm.
Alarm is Remind. Error
[0xC6E (3182)]
A condition that caused
the alarm to sound is
continuing to remind
the user.
Press the Alarm Mute
button on the ops panel
and isolate the cause of
the alarm.
Alarm is On Contin-
uous.
Error
[0xC6E (3182)]
A condition caused the
alarm to sound.
Press the Alarm Mute
button on the ops panel
and isolate the cause of
the alarm.
SES access fault
tolerant: Multiple paths
are available for gath
-
ering this enclosure’s
status information.
Information
[0xCFD (3325)]
An enclosure is now
SES fault-tolerant.
No action necessary.
SES access not fault
tolerant: If this enclo-
sure’s SES enabled
drive fails then no
information about the
status of this enclosure
will be available.
Warning
[0xCFE (3326)]
An enclosure was
found to have only one
available SES drive.
Press the Alarm Mute
button on the front
panel.
Ensure that both slot
1 and 7 have SES
compatible drives
installed.
Ensure that the SES
drives installed in slots
1 and 7 are operational.