User guide

128 Event Logs
Enclosure Event
Messages
Type [ID] Cause Action
Power supply <zz> is
OK.
Information
[0xC6B (3179)]
Normal condition
reported.
No action necessary.
Power supply <zz> is in
a critical state.
Warning
[0xC6B (3179)]
The specific power
supply has failed.
The specific power
supply is powered off.
Replace the power
supply.
Ensure that the specific
power supply On/Off
button is in the On
position ( l ).
Power supply <zz> is
not installed.
Error
[0xC6B (3179)]
The power supply was
removed.
Re-insert the power
supply, connect the AC
power cord and power
on the power supply.
Fan <zz> is OK.
Information
[0xC6C (3180)]
Normal condition
reported.
No action necessary.
Fan <zz> is in a critical
state.
Error
[0xC6C (3180)]
A specific fan failure.
Total fan failure.
Cooling fan module
was removed.
Replace the cooling fan
module.
Re-inset the cooling fan
module.
Temperature sensor
<zz> is OK.
Information
[0xC6D (3181)]
Temperature sensors
are reporting normal
temperatures in the
enclosure.
No action required.
Temperature <zz> is
operating outside of
specifications.
Warning
[0xC6D (3181)]
Temperature sensors
are reporting enclosure
temperatures have
reached the threshold
of 50 °C.
Ensure that both
cooling fans are
operating normally.
(Replace if needed.)
If the fans are set
to automatic speed
control, place the
jumper on the Cooling
fan module circuit
board to force the fans
to high speed.
If the environment
ambient temperature
is high, reduce the
ambient tempera-
ture. Ensure that the
airflow is not blocked
or restricted on the
enclosure.