These events are related to the enclosure components reported by the SES processor or SAF-TE
processes (SCSI). The type [ID] format is: Event type name with its associated ID expressed in
[hexadecimal (decimal (displayed in the OS))].
Enclosure Event
Messages
Type [ID] Cause Action
No SES drives were
found which means
no enclosure status
information can be
reported. This could be
due to the SES slot(s)
in the enclosure having
no drives installed or
the drives are malfunc-
tioning. It may also be
due to a drive target
ID conflict. Check the
enclosure(s) drive’s
hard target ID setting.
Error
[0xB59 (2905)]
No drives installed in
slots 1 or 7.
Enclosure ID conflict.
Insert a disk drive in
either or both drive
slots 1 and 7.
Check the enclosure ID
on all enclosure(s).
Enclosure<xx> (w/
WWN:<xx xx xx xx xx
xx>) timed out on SCSI
command.
Error
[0xB79 (2937)]
This error is generated
when a command to
the Enclosure proc-
essor timeouts.
Verify if the system has
gone to SES_LEVEL_1.
If it has, verify the
configuration.
Faulty cables, drives
or Drive I/O Interface
Module malfunction
could be the root cause
of this error.
You may occasion
-
ally see this error
during drive insertion,
failover/ failback or
drive removal. As long
as the system remains
at SES_LEVEL_3 the
user does not inter-
vene. If this event is
periodically posted in
the event log the user
may have a hard drive
or Disk I/O Interface
Module problem. The
system should be
inspected to isolate
the problem to either
drives or Disk I/O Inter-
face Module.
NOTE: This event is