User guide
125MAXDATA SR1202 M1 – StorView
®
RAID User Guide
Drive & Array Event
Messages
Type [ID] Cause Action
(SATA Drives Only)
SATA Drive Error: (Slot
<number>) Information
<description>.
Error
[0xB75 (2933)]
Drive or SATA link
error.
No action necessary.
(SATA Drives Only)
A drive w/ SN (SAS:
w/ WWN) <xx xx>
(Slot <nn>) has been
removed.
Error
[0xB76 (2934)]
A drive w/ WWN <xx
xx> (Slot <nn>, Enclo-
sure <nn>) has been
removed.
No action necessary.
There was a bad block
during a rebuild on
Array <nn>, Drive
<mm>, LBA <xx xx xx
xx xx xx>, Block Count
<xx>.
Error
[0xB78 (2936)]
A bad block was
detected during the
rebuild operation. Data
loss will occur with that
data stripe.
Replace drive after
rebuild. Restore lost
data from a know good
backup.
Controller Port Events
These events are related to the host side Controller Port. The type [ID] format is: Event type name
with its associated ID expressed in [hexadecimal (decimal (displayed in the OS))].
Controller Port Event
Messages
Type [ID] Cause Action
Host Loop 0/1 acquired
Loop ID <xx> because
we were not able to get
Loop ID <xx> (as speci
-
fied in the controller
settings).
Error
[0xB17 (2839)]
[0xB18 (2840)]
Address conflict with
either host adapter
orother device on the
same loop.
Resolve address
conflict.
A LIP has occurred
on Host loop <xx>.
Reason: <type>, The
LIP was repeated <yy>
times.
Information
[0xB24 (2852)]
A LIP was generated so
that a loop port could
acquire a physical
address on an arbi-
trated loop.
A LIP was generated
by port ID: <xx> so that
the loop would be re
initialized.
A LIP was generated
because of a loop
failure.
A LIP was generated by
port ID: <xx> because
of a loop failure.
No action necessary.
Host Loop <xx> is now
up.
Information
[0xB25 (2853)]
Loop is becoming
ready.
No action necessary.
Host Loop <xx> is
down.
Information
[0xB26 (2854)]
Loop is going down. Check/replace the cable.