User guide

121MAXDATA SR1202 M1 – StorView
®
RAID User Guide
Drive & Array Event
Messages
Type [ID] Cause Action
Rebuilding has failed
due to an unrecover
-
able error on the new
drive w/SN (SAS: w/
WWN) <xxxxxx> (Slot
<nn>, Enclosure <nn>)
(<Array Name> Drive
<num>).
Error
[0xB0D (2829)]
Typically due to a
non-recoverable media
error or hardware error.
Backup all data and
restore to a new array.
The drive w/SN (SAS:
w/ WWN) (Slot <nn>,
Enclosure <nn>) (Slot
<number>) (Drive
<number>) has failed
due to a time-out.
Error
[0xB0E (2830)]
Drive error. Replace the disk drive.
Disabled Enclosure
<xxxxxx> Slot <nn>
due to excessive errors.
Error
[0xB13 (2835)]
This indicates that the
controller has shut-
down the slot due to
multiple errors from the
drive. This may be due
to a bad drive or MUX
Transition Board.
Remove the drive in the
identified slot to reen-
able it.
SATA Multiplexer
switching failure on
Enclosure <xxxxxx>
Slot <nn>.
Error
[0xB13 (2835)]
This indicates that the
controller has tried
multiple times to switch
the Multiplexer on a
SATA drive and it has
not been successful.
This may be due to a
bad drive or MUX Tran
-
sition Board.
Replace the disk drive
or MUX Transition
Board.
Array <name> is in a
critical state.
Error
[0xB1B (2843)]
Drive removal or
failure.
Replace the disk drive
and rebuild the array.
The drive w/SN (SAS:
w/ WWN) <xx xx xx xx
xx xx> (Slot <number>)
returned a bad status
while completing a
command. SCSI Info:
Operation <type>,
Status <type>.
Error
[0xB27 (2855)]
Unknown status
returned by the disk
drive.
Contact technical
support and provide
them with a copy of the
event log.
The drive w/SN (SAS:
w/ WWN) (Slot <nn>,
Enclosure <nn>) timed
out for the SCSI Opera-
tion <type>.
Error
[0xB28 (2856)]
Drive hardware error or
bus error.
Check cabling and
ensure the disk drives
are properly seated.