User guide
120 Event Logs
Controller Events
Messages
Type [ID] Cause Action
An SDRAM ECC error
- bit <xx> at address
<xx,xx,xx,xx.xx> has
been detected and
corrected.
Warning
[0xB72 (2930)]
SDRAM error. If it repeats, replace the
controller.
A configuration param-
eter has been changed:
<array name> (Array
<array number>) has
been trusted due to
a cancellation of an
initialization.
Information
[0xB74 (2932)]
A user cancelled an
initialization
No action necessary.
Hardware Error
Additional Info: 0x<xx>
0x<xx> 0x<xx> 0x<xx>
Error
[0xB7a (2938)]
The controller will
continue to function,
however the SES
temperature sensing
may not function prop-
erly.
Replace the controller.
Drive and Array Events
These events are related to the drives, loops (where applicable) and disk arrays. The type [ID] format is:
Event type name with its associated ID expressed in [hexadecimal (decimal (displayed in the OS))].
Drive & Array Event
Messages
Type [ID] Cause Action
The drive w/SN (SAS:
w/ WWN) <xxxxxx>
(Slot <nn>, Enclo-
sure <nn>) (<Array
Name> Drive <member
index>) has failed due
to an unrecoverable
error. Sense Data:
<xx>/<xx>/<xx>.
Error
[0xB0A (2826)]
Typically due to a
non-recoverable media
error or hardware error.
Replace the disk drive.
The drive w/SN (SAS:
w/ WWN) <xx xx xx xx
xx xx> (Slot <number>)
(Drive <number>)
has been marked as
failed because it was
removed.
Error
[0xB0B (2827)]
Drive has been
removed by the user, or
has a serious hardware
error.
Removal of cables
connecting the enclo-
sures.
Replace the disk drive.
Replace the cables.
Rebuilding has failed
due to an unrecover
-
able error on the new
drive w/SN (SAS: w/
WWN) <xxxxxx> (Slot
<nn> (Drive <number>)
in the array.
Error
[0xB0C (2828)]
Typically due to a
non-recoverable media
error, or hardware
error.
Replace with a new
drive and initiate a
rebuild.