Quick Start Guide

SuperLoader 3 Quick Start Guide
SCSI Bus Requirements 0
You must connect the autoloader to one of the following
SCSI bus types:
Ultra 320 SCSI-3, LVD SE SCSI bus
Ultra 160 SCSI-3, LVD SE SCSI bus
General Information
0
Your SCSI host adaptor card must also support the SCSI bus
type used to connect the autoloader. If you use a LVD SCSI
bus, use a host adapter card with a connection for a high-
density (HD) 68-pin cable.
Accessories 0
The following accessories are shipped with the Quantum
SuperLoader 3 autoloader:
Quantum SuperLoader 3 Quick Start Guide
•SCSI host cable
SCSI terminator
Hardware to rack mount the autoloader
•TORX
®
L-Key drivers (T8 and T10)
•One magazine blank
Power cable
Documentation CD containing all of the documentation
in Adobe
®
Portable Document Format (PDF)
Bar code labels
N
OTE: The autoloader is not compatible with a
High-voltage Differential (HVD) SCSI bus.
N
OTE: If you use a single-ended (SE) SCSI bus, the tape
drive’s performance is limited to the maximum data
transfer speed of the bus.
The maximum number of autoloaders supported per
SCSI bus is two.
The autoloader may not work with multiple SCSI
LUNS when attached to a RAID controller. The
autoloader is not recommended for use with a RAID
controller. If this problem occurs, it is recommended
that the autoloader be attached to a separate SCSI
bus controller on the host or server.
Choosing a Location 0
The autoloader is designed to fit in a standard 19-inch rack
using either the long or short brackets (depending on the
depth of the rack), or the optional rail kit. Choose a location
that meets the following criteria. The autoloader uses
standard rack mounting hardware.
Table 1 Location Criteria
UL Requirements 0
Elevated Operating Ambient
Tem p er at ur e
0
When installed in a closed multi-unit rack assembly, the
operating ambient temperature of the rack environment
may be greater than the room ambient. Therefore,
consideration should be given to installing the equipment in
Criteria Description
Rack
requirements
Standard 19-inch rack with 2U of
clearance.
Room
temperature
10–35° C (50–95° F)
Power source AC power voltage: 100–127 VAC; 200–
240 VAC
Line frequency: 50–60 Hz
NOTE: Locate the AC outlet near the
autoloader. The AC power cable is the
product’s main disconnect device and
must be easily accessible at all times.
Weight 14.1 kg (31 lb.) unloaded
17.2 kg (38 lb.) loaded with 2
magazines, 16 cartridges
Air Quality Minimize sources of particulate
contamination. Avoid areas near
frequently used doors and walkways,
cooling or exhaust vents, stacks of
supplies that collect dust, printers, and
smoke-filled rooms.
C
AUTION: Excessive dust and debris can
damage tapes and tape drives.
Humidity 20–80% RH (non-condensing)
Clearance Back: Minimum of 43.2 cm (17 in.)
Front: Minimum of 68.6 cm (27 in.)
Sides: Minimum of 5.08 cm (2 in.)