User`s manual

MF 75MAXDATA PLATINUM 7200 IR M6Replacing the CMOS Battery
6 Replacing the CMOS Battery
The lithium battery on the Main Board powers the real-time clock (RTC) for three to four years in
the absence of power. When the battery weakens, it loses voltage and the system settings stored
in CMOS RAM and the Real Time Clock (such as the date and time) can be wrong. Contact your
customer service representative or dealer for a list of approved replacement batteries.
The following warning and translations are required by specific certifying agencies to be printed
immediately adjacent to the procedure for removing the battery.
CAUTION
Risk of explosion if the battery is replaced with an incorrect type. Batteries should be recycled
where possible. Disposal of used batteries must be in accordance with local environmental
regulations.
VORSICHT
Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf
nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp
ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers
entsprechend.
PRÉCAUTION
Risque d’explosion si la pile usagée est remplacée par une pile de type incorrect. Les piles
usagées doivent ętre recyclées dans la mesure du possible. La mise au rebut des piles
usagées doit respecter les réglementations locales en vigueur en matičre de protection de
l’environnement.
OSTRZEŻENIE
Istnieje niebezpieczeństwo wybuchu w przypadku zastosowania niewłaściwego typu baterii.
Zużyte baterie należy w miarę możliwości utylizować zgodnie z odpowiednimi przepisami
ochrony środowiska.
1. Observe the safety precautions, warnings, and cautions described in “Safety Information”.
2. Turn off all peripheral devices connected to the system.
3. Power down the system and unplug both AC power cords.
4. Remove the top cover. For instructions, see “Removing the Top Cover”.
5. Remove the Memory Board or the Memory Board air baffle from Slot A to expose the battery.
For instructions, see “Cold Removal of Memory Board”.
6. Place your finger on the edge of the battery, between the two smaller prongs that hold the
battery in place.
7. Without pulling up on the battery, push the battery toward the larger prongs until the edge of
the battery clears the small prongs.
8. Maintain pressure on the battery while pulling up on the released edge of the battery to lift it
from the server. See Figure 13.