User`s manual

66 67MAXDATA PLATINUM 7200 IR M6User Serviceable Platform Components
66 67MAXDATA PLATINUM 7200 IR M6User Serviceable Platform Components
Installing and Removing the Fibre Channel Module
Removing the Fibre Channel Module
1. Observe the safety precautions, warnings, and cautions described in “Safety Information”.
2. Turn off all peripheral devices connected to the system.
3. Power down the system and unplug both AC power cords.
4. Remove the top cover. For instructions, see “Removing the Top Cover”.
5. Disconnect any cables attached to the Fibre Channel Module.
6. Remove the Memory Board or Memory Board air baffle from Slot C. For instructions, see
“Cold Removal of Memory Board”.
7. Rotate the retention lever at the rear of the Fibre Channel Module slot into the up position.
8. Pull up on the Fibre Channel Module to remove it.
9. Place the Fibre Channel Module inside a static-free plastic bag on a clean, static-free work
surface.
10. Install an expansion slot cover over the empty slot or install a replacement Fibre Channel
Module:
- To install an expansion slot cover: align the cover with the slot from the rear of the chassis.
Press the cover into the slot. Rotate the retention lever at the rear of the Fibre Channel
Module slot into the down position.
- To install a replacement Fibre Channel Module: see “Installing the Fibre Channel Module”.
11. Install the Memory Board or Memory Board air baffle into Slot C. For instructions, see “Cold
Insertion of a Memory Board”.
12. Install the top cover. For instructions, see “Installing the Top Cover”.