User`s manual
50 51MAXDATA PLATINUM 7200 IR M6Server Platform Utilities
50 51MAXDATA PLATINUM 7200 IR M6Server Platform Utilities
Serial/Modem Configuration Screen 3 - Configuring Alerting
over a Serial/Modem Connection
This screen allows you to continue to enter the necessary settings to configure the serial/modem
channel. The Continue button is disabled/grayed out until all edit boxes on the screen have data
entered.
• Enable Serial/Modem Paging Checkbox: The Enable Serial/Modem Paging checkbox allows
you to enable Serial/Modem paging. When checked, the remaining controls on this screen are
also enabled so that Serial/Modem paging can be configured. If this checkbox is cleared, all
controls are disabled and Serial/Modem paging shall be disabled on the server.
• Alert Destination Phone Number Edit Box: The Alert Destination Phone Number edit box
allows you to enter the phone number of the system that is to receive Alerts through a serial/
modem connection.
• Paging String Edit Box: The Paging String edit box allows you to enter the paging string
that contains the characters that are sent once the connection has been made. The length of
the Paging String is determined at run time. The paging string is concatenated with the Alert
Destination Phone Number entered on this screen. Therefore, it is not necessary to enter the
Alert Destination Phone Number with the Paging String.
• Blackout Period Edit Box: The Blackout Period edit box allows you to enter the time, in
minutes, between successive pages. The valid range is [0 - 255] where 0 disables the blackout
period.
• Alert Paging Filters: If you press the Alert Paging Filters button, the SCW will display the next
screen with which you can check the filters that are to be used when sending out alerts.
See “LAN Channel Configuration Screen 3 - LAN Alerting Setup” for further information.