Cooling Subsystem
CAUTION
The chassis top cover must be installed for proper system cooling. Cooling components must be hot-
swapped within two minutes. This time period applies only to the time that the cooling component
is physically removed, not from the time of failure.
The cooling subsystem consists of hot-swap, redundant (2+2) fans. In the event of a cooling component
failure, system cooling is maintained and the system continues to operate while the component is
being hot swapped. Each fan module has a single LED to indicate its status. The LED will be off when
both fans are operating normally. The LED will illuminate amber if one or both of the fans fails. Failed
fans can be hot-swapped from the front of the chassis.
For proper processor cooling, the processor duct must always be in place. Systems not fully-configured
with four processors and four Memory Boards should have the processor heat sink and Memory
Board fillers installed to maintain proper cooling.
Hot-swap PCI Slots
The five hot plug PCI slots have power and attention LEDs. The attention button is used to invoke a
hot-plug sequence to remove or add an adapter without having to use the software interface. They
are identified by the green arrow on the PCI divider label. The status of the LEDs is shown in Table
8 and Table 9.
Table 8. Power Indicator
Green Power LED State Definition
Off Power off: Power has been removed from the slot. A card can be
inserted or removed.
On Power on: The slot is powered on. A card cannot be inserted or
removed.
Blinking Power transition: The slot is in the process of powering up or down. A
card cannot be inserted or removed.
Table 9. Attention Indicator
Amber Attention LED State Definition
Off
Normal: Normal operation
On Attention: Power fault or operational problem has occurred with this
slot.
Blinking Locate: The slot is being identified at the users request.
NOTE
If you hot-remove a PCI card without following the proper procedure, power will automatically be
turned off to the slot.