User`s manual

13MAXDATA PLATINUM 5220 Server
Descriptions of the front panel LEDs are listed in the following table.
Table 4. Front Panel LED Descriptions
LED Name Color Condition Description
Power/Sleep LED
Green ON Power on
Green BLINK Standby/Sleep (S1)
OFF Off (also Sleep S4)
Status
Green ON System ready
Green BLINK System ready, but degraded: some CPU fault, DIMM
killed
Amber ON Critical alarm: Critical power module failure, critical
fan failure, voltage (power supply), voltage and
thermal fault
Amber BLINK Non-critical failure: Redundant fan failure, redundant
power failure, non-critical power and voltage
OFF System not ready: Post error/NMI event/PCI or termi-
nator missing
Hard drive activity
Green BLINK Hard drive activity
Amber ON Fault
OFF No activity
NIC1 activity Green ON Linked
Green BLINK LAN activity
OFF Idle
NIC2 activity Green ON Linked
Green BLINK LAN activity
OFF Idle
ID LED (rack only)
Blue BLINK Server identification; Toggled by ID button or soft-
ware
OFF Server identification; Toggled by ID button or soft-
ware