User`s manual

41MAXDATA Server PLATINUM 1500 IR M6
7 Technical Reference
Power Supply Specifications
600 W Single Power Supply Input Voltages
100-127 V at 50/60 Hz; 8.55 A max.
200-240 V at 50/60 Hz; 4.3 A max.
600 W Single Power Supply Output Voltages
The table below lists the total wattage available from the power subsystem for each voltage. Ensure
that your loads do not exceed the combined total wattage of 600 Watts.
Table 9. Power Supply Output Capability
Voltage Maximum Current
+3.3 V 15 A
+5.0 V 30 A
+5 V Standby 3 A
+12.0 V (4 rails) 44 A (20 A for one rail)
–12.0 V 2.0 A
CAUTION
Do not exceed a combined power output of 90 Watts for the +5 V and +3.3 V outputs. Exceeding
a combined 90 Watts will overload the power subsystem and may cause the power supplies to
overheat and malfunction.
The expansion slots on the server board are rated for no more than 25 Watts for any one slot. The
average current usage per slot should not exceed 13 Watts.
System Environmental Specifications
Table 10. Environmental Specifications
Temperature Non-operating –40 °C to 70 °C.
Operating 10 °C to 30 °C; derated 0.5 °C for every 1000 ft
(305 m) to a maximum of 10,000 ft.
Humidity Non-operating 90 % relative humidity (non-condensing) at 30 °C.
Acoustic noise 7 Bels in sound power for a typical office ambient
temperature (18–24 °C). The selection of periph-
erals may change the noise level.