Product guide

90 Configuration Software and Utilities
91MAXDATA PLATINUM 90004R Server System
Enable PEF
This option is used to globally enable or disable platform event ltering.
Enable SEL Event Messages for PEF Actions
When this option is checked, each action triggered by a lter generates an event message for the
action. This allows the occurrence of PEF-triggered events to be logged in the System Event Log (if
event logging is enabled).
PEF Startup Delay
This option is used to congure the time in seconds to delay platform event ltering after a system
power up or reset. The range is 60 to 255. The default is 60 seconds.
Alert Startup Delay
This setting is used to congure the time in seconds to delay sending out alerts after a system power
up or reset. The range is from 0 to 255, where 0 indicates no delay.
PEF Action Global Settings
This set of checkboxes globally enables PEF actions that can occur when an event lter is triggered.
Note that for a lter to trigger a particular chassis action (power cycle, reset, power down, or diagnostic
interrupt), the global setting in this view must be enabled and that chassis action must be selected
for that lter (in the event lter settings view; refer to the next section).
The checkboxes allow enabling or disabling of the following:
Power Cycle
If checked, this checkbox globally enables the Power Cycle action when an event lter is triggered.
Reset
If checked, this checkbox globally enables the system reset action when an event lter is triggered.
Power Down
If checked, this checkbox globally enables the system power down action when an event lter is
triggered.
Diagnostic Interrupt
If checked, this checkbox globally enables a diagnostic (non-maskable) interrupt when an event lter
is triggered.
Alert
If checked, this checkbox globally enables alerts when an event lter is triggered.