Table 17. Abbreviations Used in Hex Mode Display
RID Record ID
RT Record Type
TS Time Stamp
GID Generator ID
ER Event Message Format Revision
ST Sensor Type
SN Sensor Number
EDIR Event Dir and Event Type
ED1 Event Data 1
ED2 Event Data 2
ED3 Event Data 3
MID Manufacturers ID (used when displaying OEM SEL records type C0h-DFh)
OEM OEM defined (used when displaying OEM SEL records type C0h-DFh and
E0h-FFh)
The SEL Viewer main window contains a display window that displays all the SEL records. It also
contains a pull-down menu, used for selecting the functions available in the SEL Viewer. You can move
between the display window and pull-down menu using the function key <F10>. From the menu,
you can use the arrow keys to move around the various menu items, and use return key to select a
particular menu item. A brief help message about the option selected from the menu is displayed at
the bottom of the SEL Viewer main window.
The display window supports arrow keys, <PgDn>, <PgUp>, <Home>, and <End> keys to pan across
the display window. It also supports the <F5> key to move forward between columns and <F6> to
move backwards.