Product guide

24 System Description
25MAXDATA PLATINUM 90004R Server System
Power Supply LED Indicators
Each power supply module has three status LEDs the location and operating conditions for which
are shown in Figure 10.
OM12887
A CB
Figure 10. Power Supply Indicators
A. Power LED (green) On - indicates the presence of DC power in the system
Blinking - indicates the system is in ACPI sleep mode
Off - indicates the power is turned off or the power source is
disrupted
B. Failure LED (amber) Indicates a power supply failure
C. Predictive Failure LED (amber) Indicates a power supply failure is imminent
Table 6. Power Supply LED Status Indicators
A
(PWR)
Power Supply
(Green LED)
B
(FAIL)
Power Supply Fail
(Amber LED)
C
(PFAIL)
Predictive Failure
(Amber LED)
No AC power to all PSU OFF OFF OFF
No AC power to this PSU only or PS
failure
OFF OFF ON
AC present / Standby Output On Blinking OFF OFF
Power supply DC outputs ON and
OK
ON OFF OFF
Current limit ON OFF Blinking
Predictive failure ON Blinking/Latched OFF
NOTE
Proper system cooling requires that the power supply bay be lled either by two power supply
modules, or a power supply module and a ller panel.