Service manual

Belinea 101910
3.5. ELECTRICAL SPECIFICATIONS
3.5.1 Standard conditions
Display area (HxV)
1280 x 1024 Display mode
More than 30 Warming up time
AC 230,50Hz Input voltage
25 +/- 5 C degrees Ambient
100 Brightness
80 Contrast
0.7 Vpp Video signal level
376.32 x 301.06 mm
3.5.2 POWER
3.5.2.1 Power supply
Input voltage: 100 - 240 V AC
Input current: max. 0.8 Arms
Output voltage: 12VDC, 3.25A
Frequency range: 47 - 63 Hz
Inrush current: Shall be less than the ratings of critical components
(including fuse, rectifiers and surge limiting device)
for all conditions of line in voltage.
Maximum power consumption: 45 Watts
3.5.2.2 Power Management
The Power Management System complies with TCO ‘03 standards.
MODE H-SYNC V-SYNC COLOR OF
POWER LED
POWER
CONSUMPTION
RECOVERY TIME
On Active Active Green < 45 Watts -
Off Inactive Inactive Amber < 1 Watts < 5 seconds
Remark: In case of “no signal“ Power LED must be amber.
At first power on w/o signal LED will be green + message on screen.
MAXDATA Servicemanual 111908 Page 11