Datasheet

MaxBotix
®
Inc.
Copyright 2005 - 2021 MaxBotix Incorporated
Patent 7,679,996
ParkSonar
®
-EZ Series
Page 5
Web: www.maxbotix.com
PD13426g
MaxBotix Inc., products are engineered and assembled in the USA.
Timing Description
The ParkSonar-EZ sensor is ready to accept the RX command 250mS after power-up. If the RX pin is left open or held
high, the sensor will first run a calibration cycle (49mS) and then it will take a range reading (49mS). After the power up
delay, the first reading will take an additional ~100mS. Subsequent readings will continue to occur every 50ms to
~1 second.
When an object is placed in the sensor detection zone, the sensor will acquirethe target in ~10 seconds and begin
sending the appropriate serial output and set the PW pin high.
If the detected object then leaves the sensor detection zone the sensor will releasethe target ~5 seconds later. At this
time, the PW pin will be set low. Release time can be influenced by other nearby sensors and may appear to be longer in
applications with many nearby sensors.
_______________________________________________________________________________________________________________________________________
Time