6.4.8. Send
Pattern to send must be selected on the list and then confirmed with OK or F2 key. There is
additional warning to confirm if:
pattern wasn’t tested or didn’t passed all tests,
pattern includes no delay detonators,
not all detonators were programmed in pattern from PC.
Empty patterns are not listed to send.
Next step depends on medium chosen in transfer settings.
For USB there will be message to connect USB cable. In this moment USB cable should be
connected to the Blaster. If Blaster waits for transmission transfer will be started
immediately. Connecting USB cable earlier my cause entering to mass storage mode. Logger-
Logger transmission can be only realised by NFC.
For NFC there will be message to align NFC device. Logger should be placed on Blaster’s NFC
antenna or put to another Logger’s back to start the transmission.
6.4.9. Receive
Receiving pattern have to be confirmed with OK or F2 key. Logger will start receiving by NFC
regardless from the option set up in transfer settings. Logger should be put to another
Logger’s back to start the transmission.
6.4.10. Program range
Program range is to set or change delay time in a part of pattern. This is specially to set delay
time of no delay detonators, but it works also with detonators with delay time already set.
To use program range function user has to set first and last detonator in active pattern,
initial delay and increment. Pressing OK or F2 will change the delay time in pattern only. To
transfer this change to detonators test range or test pattern functions have to be used.
6.5. Settings
Settings menu is to change setting of Logger listed below.