3.1.8. Firing the blast
Before firing the blast, recheck it (leakage, connected and missing detonators…) using
the RIOTRONIC X+ Logger. If an error is found on these tests do not begin the blast
procedure. Stop and solve the error first.
NEVER use the Blaster to check the blast near the blast area. Use the Logger instead.
Be sure that the blast area has been cleared and secured.
Locate the firing point in a safe area and use a shelter or protection.
Consider wind direction to avoid fumes from the blast.
Proceed with the firing procedure:
o Secure the firing line in order to avoid the RIOTRONIC X+ Blaster being
dragged by the blast-generated movement.
o Check the blast using the RIOTRONIC X+ Logger.
o Get the security key.
o Connect the RIOTRONIC X+ Blaster to the RIOTRONIC X+ Logger and
download the data. If more than one RIOTRONIC X+ Logger has been used
while programming, download data from each one.
o Proceed with checking and charging.
o Once the charging operation has been completed, make sure the area is clear
and fire.
o Wait inside the protection for at least one minute to avoid fly rock. Do not
enter the blast area for at least five minutes after the blast.
3.1.9. Post blast inspection and solving cut-offs/misfires
Make sure that fumes have disappeared.
Check whether cut-offs or misfires have happened.
If there are no irregular situations give the “All clear” order.
If not, proceed with the misfire remediation procedure.
In any case, always wait for at least FIVE minutes to step into the blast area after the
blast.
3.1.10. Blast history/record download
Download the blast history from both the RIOTRONIC X+ Logger(s) and the
RIOTRONIC X+ Blaster(s).
Keep them with the corresponding blast report.