Operation Manual

SFX SERIES USER’S GUIDE
Rev 2.2 125
Edit Field Description
For special DVB systems and for added flexibility, you may need to enter a PID number for the
PAT that is something other than PID 0. This field is provided for that purpose and if left
untouched, will default to 0.
Figure D- 5 Edit Conditional Access Configuration Page
Front Panel LED Indications
When the DVB CAS Option is installed, certain indicators on the front panel will behave differently and provide
additional status information, as follows:
Indicator Description
OPTIONS Purpose: provides status of the CAS operation.
Colour: off/green, where:
Solid Green – CAS option is installed.
Flashing Off/Green – PAT/PMT tables are being received.
Off – the CAS option is not installed.
NETWORK Indicator colours are enhanced as follows:
Flashing Off/Green – satellite network interface is authorized and there is data activity on one or more
of the selected MPE PIDs. If the CAS option is installed, this also indicates that the data is being
decrypted.
Flashing Off/Orange – CAS option is installed, satellite network interface is authorized and there is
data activity on one or more of the selected MPE PIDs. However, the data is not being decrypted.