T-Max® Manager/Pro and T-Max® 3A User’s Guide Page 9
Note: If the T-Max® Mgr/Pro is controlled by a computer, the Delay and Auto Start
mode are controlled by the computer’s software unless you set the T-Max® Mgr/Pro to
infinite delay. If the T-Max® Mgr/Pro is set to Infinite Delay, the Delay set in the T-
Max® Mgr/Pro or the PC will be ignored.
8) The following message will appear: MGR MAX BED. Enter the maximum bed number
followed by the Enter key.
This number must be equal to or higher than the highest address that a T-Max® 3A is set
to. For example if you have six beds, but are addressing the T-Max® 3As to 1,2,3,4,5,
and 8, then set the maximum bed number to 8.
9) The following message will appear: MANAGER NUM. Enter the T-Max® Mgr/Pro
address, followed by the Enter button.
Up to 8 T-Max® Mgr/Pro’s can be connected in a single salon. One T-Max® Mgr/Pro
must be set to address 0. All slave T-Max® Mgr/Pro’s must be set to an address other
than 0. Set each Slave T-Max® Mgr/Pro to a unique address.
10) The following message will appear: MGR RE-SCAN TIME. Press the Enter key
(without entering a number)
11) The following message will appear: MAX SLAVE. This should be the same number as the
highest address you have set any slave T-Max® Mgr/Pro’s to. For example, if you have three
T-Max® Mgr/Pro’s, one must be set to address 0 (Master). If one slave T-Max® Mgr/Pro is
set to 1 and the other is set to 3, the MAX slave value should be 3. The highest value that can
be entered is 7. Enter the MAX SLAVE number followed by the Enter button.
The VFD display will then read “Saving Params”.
12) Cycle power to the T-Max® Mgr/Pro.