T-Max® Manager/Pro and T-Max® 3A User’s Guide Page 8
4.2 T-Max® Mgr/Pro
1) Make sure all wiring is completed. Refer to Section 3 for wiring instructions.
2) Make sure that the modular cable running to Room 1 is connected to the modular connector
on the T-Max® Mgr/Pro (Refer to Figure G, Section 12.7).
3) Apply power to the T-Max® Mgr/Pro.
The T-Max® Mgr/Pro will scan for T-Max® 3As. An amber light will illuminate for each
T-Max® 3A detected. Once scanning is complete, the light will turn green.
5 MANUAL OPERATION
5.1 Description
The T-Max® Mgr/Pro has 64 dual-colored lights showing bed status. Section 5.8 describes
the light indicators.
A 16x2 VFD display on the upper right corner of the T- Max® Mgr/Pro shows bed status and
times. A 16 key keypad allows the user to control the salon.
5.2 Initial Configuration
5.2.1 Setting up the T-Max® Mgr/Pro.
1) Apply power to the T-Max® Mgr/Pro. The T-Max® Mgr/Pro will scan the network to find
all T-Max® 3As.
2) Press the Call/Menu Button. The following message will appear: Security#.
A sheet was provided showing the factory default settings for each security level and
security level descriptions. You must go to security level 3.
3) The following message will appear: GET PARAMS? Press Next.
4) The following message will appear: SEND PARAMS? Press Next
5) The following message will appear: MGR PARAMS? Press Enter.
6) The following message will appear: MGR DELAY TIME. Enter the delay time in minutes,
followed by the Enter button.
If you want the session to start right away, enter a delay of 0. The maximum setting for
delay is 10 minutes. This setting is for every bed in the salon.
7) The following message will appear: MGR START MODE. Enter the desired Auto Start
Mode followed by the Enter button.
This setting is for every bed in the salon. If a 1 is entered, then the bed will energize
immediately after the delay time expires. If a 0 is entered, the bed will not energize when
the delay time expires, but session time will begin counting down (if a 0 is pressed, the 0
will not appear on the display). If a 2 is entered, then the T-Max® Mgr/Pro is set to
infinite delay and session will not start until the Start/Stop button is pressed on the T-
Max® 3A.